Research Development Manufacturing Operations Maintenance Management
EXPERIMENTAL STUDY OF INFLUENCE OF FINE DROP MOISTURE AND CONTAMINANTS IN HEAT CARRIER ON COEFFICIENT OF HEAT REMOVAL OF VORTEX HEAT EXCHANGER OF GAS CONTROL STATION HEATING SYSTEM
Scindeks Assistant Scindeks Assistant — A system for serious journals and those aspiring to become one
PDF

Abstract

Experimental studies of fine drip moisture and contaminants influence in the heat carrier on the heat transfer coefficient in the vortex heat exchanger of the heating system of gas control room were described. Pilot studies were carried out in two stages.

At the first stage, the test values of coolant temperature decrease were analyzed due to heat removal for evaporation and heat transfer coefficient under idealized conditions without taking into account the effect of fine moisture and contaminants on the process of heat transfer to the blades in the vortex heat exchange apparatus.

At the second stage, the heat transfer coefficient was studied under conditions close to actual operating conditions of vortex heat exchange element, when fine moisture and specific contaminants are in the natural gas which is in contact with water.

As a result of the first stage of experimental studies, it was found that experimental values of heat carrier temperature decrease due to heat extraction for liquid evaporation on the surface of swirling swirler blade in vortex heat exchanger are slightly different from those determined theoretically. And they mainly decrease.

Analysis of the heat transfer coefficient values under idealized conditions, obtained experimentally and calculated theoretically, shows their satisfactory convergence. This convergence is measurement error and data calculation.

As a result of the second stage of pilot studies it was revealed that availability of disperse moisture increases heat transfer coefficient in 1,4%1,9 times. There is evaporation temperature increase as the concentration of contaminants bombarding the mirror of liquids increases. This fact also intensifies heat exchange process.

Thus, as a result of experimental studies, the possibility of using a vortex heat exchange apparatus in a heating system of gas control station has been confirmed.

Keywords

Array
DOI: 10.5937/jaes18-27798

References

Autori koji objavljuju u ovom časopisu pristaju na sledeće uslove:

  1. Autori zadržavaju autorska prava i pružaju časopisu pravo prvog objavljivanja rada i licenciraju ga Creative Commons licencom koja omogućava drugima da dele rad uz uslov navođenja autorstva i izvornog objavljivanja u ovom časopisu.
  2. Autori mogu izraditi zasebne, ugovorne aranžmane za neekskluzivnu distribuciju rada objavljenog u časopisu (npr. postavljanje u institucionalni repozitorijum ili objavljivanje u knjizi), uz navođenje da je rad izvorno objavljen u ovom časopisu.
  3. Autorima je dozvoljeno i podstiču se da postave objavljeni rad onlajn (npr. u institucionalnom repozitorijumu ili na svojim internet stranicama) pre i tokom postupka prijave priloga, s obzirom da takav postupak može voditi produktivnoj razmeni ideja i ranijoj i većoj citiranosti objavljenog rada (up. Efekat otvorenog pristupa).

Downloads

Download data is not yet available.