Abstract

Diagnostics of adsorbed water vapor molar heat and accumulation at bubble surface during refinery waste water aeration treatment with membrane distributor was performed, on the basis of experimentally measured air temperature and pressure on input and exit and measured stationary oxygen content after saturation period. The working hypothesis is that electromotor and compressor favor the consumption of water vapor adsorption heat at bubbles surfaces and the relaxation with active centers transport work, according to II law of thermodynamic. During air over-pressure relaxation, active centers enable the couple of prevented exothermic hydration and favored endothermic processes and water vapor accumulation up to catalyst final titration points in zone of condensation, precipitatation, vaporization, nitrification/denitrification and biological slime that can cause diffuser fouling and scalling. Diagnostics results for the all 15 examined systems with the same membrane diffuser and various combination of process parameters, c-h-q: without and with added motor oil, c = 0 mg/l   5 mg/l   and 10 mg/l, with two heights of water column, h =1m and 2 m and with three air flows, q=2m3/h, 6m3/h and 10 m3/h verified the linear functional dependence of indicator of proper process condition, i.e.  experimental determined oxygen saturation degree on water vapor accumulation (R2=0.766).

Keywords

Array
Array
Array
Array
Array
Array
Array
Array
Array
Array
DOI: 10.5937/jaes13-8696

References

Autori koji objavljuju u ovom časopisu pristaju na sledeće uslove:

  1. Autori zadržavaju autorska prava i pružaju časopisu pravo prvog objavljivanja rada i licenciraju ga Creative Commons licencom koja omogućava drugima da dele rad uz uslov navođenja autorstva i izvornog objavljivanja u ovom časopisu.
  2. Autori mogu izraditi zasebne, ugovorne aranžmane za neekskluzivnu distribuciju rada objavljenog u časopisu (npr. postavljanje u institucionalni repozitorijum ili objavljivanje u knjizi), uz navođenje da je rad izvorno objavljen u ovom časopisu.
  3. Autorima je dozvoljeno i podstiču se da postave objavljeni rad onlajn (npr. u institucionalnom repozitorijumu ili na svojim internet stranicama) pre i tokom postupka prijave priloga, s obzirom da takav postupak može voditi produktivnoj razmeni ideja i ranijoj i većoj citiranosti objavljenog rada (up. Efekat otvorenog pristupa).

Downloads

Download data is not yet available.