Abstract
Background: Thyrotropin receptor autoantibodies (TSH-R-Ab) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO.
Methods: 87 consecutive TAO patients were enrolled and their serum samples analyzed in parallel with three assays. An ECLIA competitive binding and a chemiluminescent bridge immunoassay were used to measure total and binding TSH-R-Ab concentration, while their functional activity was determined using a stimulatory TSH-R-Ab (TSAb) cell-based bioassay.
Results: Compared to the two binding assays (ECLIA p<0.001, bridge p=0.003), the TSAb bioassay was more sensitive pertaining to the positive detection of TSH-R-Ab in TAO patients. No difference (p=0.057) was noted between the ECLIA and bridge assays regarding sensitivity rate. All patients with active and/or moderate-to-severe TAO tested positive in the TSAb bioassay (100% and 100%, respectively), while the positivity rates for bridge and ECLIA binding assays were 89.7% and 82.1% for active TAO, and 90.2% and 86.3% for severe TAO, respectively. Negative predictive values of the bioassay, bridge, and ECLIA assays were 100%, 75%, and 71%, respectively for active TAO, and 100%, 86%, and 71%, respectively for moderate-to-severe TAO. The superiority of the bioassay was most prominent in euthyroid (ET) TAO. Positivity rates of the TSAb bioassay, bridge and ECLIA binding assays were 89.6%, 75%, and 64.6%, respectively for inactive TAO; 86.1%, 69.4%, and 52.8%, respectively for mild TAO; 87.5%, 62.5%, and 12.5%, respectively for euthyroid TAO. The bridge assay correlated better with the ECLIA binding assay (ρ=0.893, p<0.001), compared to the bioassay (ρ=0.669, p<0.001).
Conclusions: In patients with TAO of various activity and severity, the TSAb bioassay demonstrates a superior clinical performance compared to both ECLIA and bridge binding assays.
Keywords
References
The published articles will be distributed under the Creative Commons Attribution 4.0 International License (CC BY). It is allowed to copy and redistribute the material in any medium or format, and remix, transform, and build upon it for any purpose, even commercially, as long as appropriate credit is given to the original author(s), a link to the license is provided and it is indicated if changes were made. Users are required to provide full bibliographic description of the original publication (authors, article title, journal title, volume, issue, pages), as well as its DOI code. In electronic publishing, users are also required to link the content with both the original article published in Journal of Medical Biochemistry and the licence used.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.